== Why is this an issue?
Moving a large string into a small field will result in data truncation with data lost from the right side of the string.
=== Noncompliant code example
[source,cobol]
----
01 ALPHA PIC X(4).
*> ...
MOVE "Now is the time" TO ALPHA *> Noncompliant. Becomes "Now "
----
=== Compliant solution
[source,cobol]
----
01 ALPHA PIC X(15).
*> ...
MOVE "Now is the time" TO ALPHA
----
== Resources
* https://cwe.mitre.org/data/definitions/704[MITRE, CWE-704] - Incorrect Type Conversion or Cast
=== Related rules